Technical product profile

SWD-4 furnace soot blower

The SWD-4 furnace soot blower is mainly used to remove dust and slagging on the water cooled wall of the boiler.

SWD-4 furnace soot blower
Steam Soot Blower

SWD-4 furnace soot blower

SWD-4

The SWD-4 furnace soot blower is mainly used to remove dust and slagging on the water cooled wall of the boiler.

ข้อมูลจำเพาะทางเทคนิค

Soot blower stroke
267mm (10.5 ")
Travel speed of soot blower
290mm/min
Soot blower speed
2.3 rpm
Each working time
2.76 minutes (1 cycle of blowing); 3.62 minutes (2 cycles of blowing); 4.49min (3 cycles of blowing)
Soot blowing medium
superheated steam or compressed air
Soot blowing pressure
~1.5MPa
Medium consumption
~30kg (1 cycle of blowing); ~60kg (2 cycles of blowing); ~90kg (3 cycles of blowing)
Number of nozzles
1
Nozzle diameter
25.4mm
Rear inclination angle of nozzle
3 °
Effective blowing radius
1.5~2m
Motor model and related parameters
YSR-6324 B5 type 0.18kw; ~1370 rpm. 380v 3P 50Hz
Weight
~110kg

รายละเอียดผลิตภัณฑ์

The SWD-4 furnace soot blower is mainly used to remove dust and slagging on the water cooled wall of the boiler. Use a single nozzle to move forward and rotate at a fixed point for soot blowing. According to the nature of ash accumulation (or slagging) and the blowing requirements of different parts of the boiler, the blowing arc, number of blowing circles, and blowing pressure of the soot blower can be adjusted to achieve the optimal blowing effect.